Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
319
3
procedure), the device writes the standard values (default setting) to the parameters
when switched on again.
3.5.2.5 Switch-On Behavior
After the b maXX
is switched on, all parameters are loaded with the stored data. The
device activates Data Set 1. Unconfigured data sets are set to default values.
3.5.2.6 Changing, Loading, Copying and Storing Parameters
Changes to parameter values (e.g. by ProDrive or via a Fieldbus) only affect the device's
working memory. If changes are also to be preserved after the next switch-on of the de-
vice, the parameters must be explicitly stored in the device. All the parameters in all the
created data sets are always stored.
With the aid of data set commands, the values of parameters in created data sets can be
loaded individually or completely into the working memory.
The data set copy function permits copying of the parameter values from a created source
data set to a different target data set. If the target data set has not been created yet, it will
be automatically created by the device. If the target data set has already been created,
the original parameter values will be overwritten.
Using the ProDrive Up/Download function on the "Data Set Management" page, param-
eters can also be saved to a PC data storage medium or written back to the device.
3.5.2.7 Identification of Parameter Set and Data Sets
There is the parameter
for identifying of the complete parameter set for a de-
vice.
For identifying individual data sets the following parameter are available:
Parameter
Data Type
Meaning
Data Set Name
STRING
Freely selectable text name for the data set
Data Set
Identification Number
UDINT
You can assign each data set (DS 1 to DS 7)
a unique number from 0 to 4294967295
here
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......