![Baumuller b maXX BM5800 Скачать руководство пользователя страница 293](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380293.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
293
3
3.5.1.4 State Transitions in the Device Controller of the axis units
0 Input to the State Machine
NOT READY TO SWITCH ON
n
Event:
m
Switch on supply to electronics
m
Hardware reset or
m
Software reset
n
Action:
m
Start initialization and self test
1 NOT READY TO SWITCH ON
SWITCH-ON INHIBIT
n
Event:
m
Initialization and self test completed without error
n
Action:
m
None
2 SWITCH-ON INHIBIT
READY TO SWITCH ON
n
Event:
– Drive activation by control word:
m
"Shut-down" command
n
Condition:
m
axis not parked
n
Action:
m
None
3 READY TO SWITCH ON
SWITCHED ON
n
Event:
– Drive activation by control word:
m
"Switch On" command
n
Condition:
m
Power supply reports operational readiness / main supply voltage applied and
n
Action:
m
None
4 SWITCHED ON
OPERATION ENABLED
n
Event:
– Drive activation by control word:
m
"Enable Operation" command
n
Action:
m
Drive function is enabled and
m
Holding brake is enabled
(only if brake is in Automatic mode (Parameter
Bit 0 = 1)
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......