Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
238
3.4
1
bit 14 Factor Group must be activated
2
bit 4 modulo actual position value must be activated
124.31
DS402 touch probe 1 pos. value
DS402 touch probe object 0x60BA
The source is selected in
.
The following scalings are possible:
m
according to
bits 2 ... 1 = 00) or
m
with the Factor Group weightings from
bit 2 ... 1 = 01) or
m
position system of the modulo actual position value
(
bit 2 ... 1 = 10)
124.32
DS402 touch probe 1 neg. value
DS402 touch probe object 0x60BB
The source is selected in
.
The following scalings are possible:
m
according to
bits 2 ... 1 = 00) or
m
with the Factor Group weightings from
bit 2 ... 1 = 01) or
m
position system of the modulo actual position value
(
bit 2 ... 1 = 10)
23 … 20 Source for DS402 touch probe 2 (TP2)
(
/
, object 0x60BC / 0x60BD)
Value:
0:
Encoder 1 trigger digital input TP1
1:
Encoder 1 trigger digital input TP2
2:
Encoder 1 trigger zero pulse
3:
Encoder 2 trigger digital input TP1
4:
Encoder 2 trigger digital input TP2
5:
Encoder 2 trigger zero pulse
6 … 15: Reserved
31 … 24 Reserved
Bit
Meaning
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......