![Baumuller b maXX BM5800 Скачать руководство пользователя страница 166](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380166.webp)
Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
166
3.4
106.52
Resolver phase synchronization
Setting of the phase shifting of the resolver tracks dependent on the DSP interrupt. Then
bit 4 of
still must be activated.
Configuration examples:
–
=
0x0003
: Resolver standard setting, resolver frequency = 7.8125 kHz
without
synchronization on the fieldbus with automatic amplitude and phase setting
–
=
0x0083
: Resolver reevaluation, resolver frequency = = 7.8125 kHz
without
synchronization on the fieldbus with automatic amplitude and phase setting
_________________________________________________________________
–
=
0x0093
: Resolver reevaluation, resolver frequency = 8 kHz
with
syn-
chronization on the fieldbus and automatic amplitude and phase setting
Here the required phase shift to the DSP interrupt with
>
106.52
<
can be set.
–
=
0x0092
: Resolver reevaluation = 8 kHz
with
synchronization on the
fieldbus. However, with an automatic phase setting and an manual amplitude set-
ting. Here the following procedure shall be complied with:
) = 1024.
2.
Set the excitation set-amplitude manually by
, until the value is
displayed at
by about 85%.
3.
Set the required phase shifting to the DSP interrupt by
>
106.52
<
.
106.60
SSI mode
Setting of transmission and the data format:
Bit
Meaning
9 ... 0
Reserved
13 - 10
Baud rate
Value
Meaning
0
100 kHz
1
199 kHz
2
399 kHz
3
1,014 MHz
4
1,974 MHz
5 ... 15
Reserved
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......