Controller terminals
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
214
7.11
m
BM4-F-ENC- 27; Encoder module SSI with 24 V encoder supply
Pin assignment encoder supply
Pin no.
Pin assignment
1
2
X1 Socket 2-pin
1
+24 V DC
2
0 V
The encoder module is provided with a synchronous-serial SSI standard interface via the
position data and parameters with a data rate of max. 1 MBit/s are exchanged between
control electronics and encoder. All encoders, are listed in
on page 123, may be used:
Power supply
24 V DC, according encoder specifi0.5 V
Signal level
differential
Permitted current input
(encoder)
max. 200 mA
Pin assignment encoder
Pin no.
Pin assignment
X2 D-sub socket 9-pin
1
Data -
2
Data +
3
Reserved*
4
Reserved*
5
Reserved*
6
+24 V DC
7
0 V
8
Clock +
9
Clock -
* do not assign
NOTE
Only if the cable break monitoring is supported (see ProDrive, page „Slot identifica-
tion“) and if the cable break monitoring is activated (see parameter handbook P0573)
both cable break and missing of the 24V power supply and a cable break in Data+/
Data- is identified. Otherwise the availability of the 24 V power supply is not checked
and a broken cable is not detected by the controller.