![Baumuller b maXX BM2500 Скачать руководство пользователя страница 680](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400680.webp)
Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
680
4.8
m
In order to inform the following axis about master-axis-sided errors at double axis units
the internal error communication can be activated by
error communication
mode.
m
Therefore the
of the following axis must be set to 2 and the
of the
master axis to 3. The following axis then will react the same as the master axis when
master axis errors occur. The master axis is however not influenced by errors of the
following axis.
4.8.13.10Flexible segments
The master and slave distances to be traversed for two selectable curve segments can
be changed by the function "flexible segments".
The curve type, the polynomial coefficients, the predecessor as well as the successor
segment cannot be influenced! Here, the values from the curve file remain applicable for
the accordant segment.
The function is activated by the bit 11 of the
Mode. The activation as well as the
deactivation is possible only at a switched off "coupled operation".
If the function is to become invalid during an activated "coupled operation" the parameters
for the selection of the flex. segment numbers Z122.30- und Z122.35- can be set to a
curve segment that is not used.
Flex. data for two segments can be set:
m
m
The flex. data must be valid at the latest before changing into the "flex. segment"!
4.8.13.11Parameter overview
Functional block:
FbCoupledMode [122]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read o
n
ly
St
o
ra
g
e
DS Supp
ort
Cyclic W
rite
122.1
Status
DWORD 0x0
0xFFFFFFFF 0x0
1:1
X
122.2
Mode
DWORD 0x0
0xFFFFFFFF 0x0
1:1
X
122.3
Master position revolutions
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1
X
122.4
Master position angle
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1
X
122.5
Active cam segment
UINT
0x0
0xFFFF
0x0
1:1
X
122.6
Sequence change start
UDINT
0x0
0xFFFFFFFF 0x0
1:1
X
122.7
Start cam segment
UINT
0
0xFFFF
0
1:1
X
122.8
Start position master revolu-
tion
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1
X
122.9
Start position master angle
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1