Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
673
4
Deleting curve data
If bit 6 is set in
the curve data is deleted. Since parameter
can only be
written if the drive is disabled, the polynomial curve can only be deleted in this state.
4.8.13.3 Changing the chaining sequence
The sequence of the single segments can be changed during operation. Two parameters
(
and
) are available for this. Based on an example this procedure is
to be explained.
It is assumed that there are five curve segments on the drive controller. Segment 1 is to
be defined as the starting segment. The specified chaining is only processing three seg-
ments currently - these segments are shown in the following table.
The segments 4 and 5 are not active at the current chaining. These shall be connected
as an alternative path to segment 2.
The parameters
and
are written to as follows:
P122.6 = 0x00010004 and P122.41 = 0x00050003 (see description of
and
After initiating the chaining change by bit 5 in the control word
the sequence is
as follows:
The active curve now consists of four segments. Segment 2 was removed from process-
ing and the segments 4 and 5 are now actively processed.
Original curve
Reloaded curve
Combined curve
1
1
1
2
2
3
3
Segment number
1
2
3
4
5
Predecessor
/
suc-
cessor
3
2
1
3
2
1
1
5
4
3
Segment number
1
4
5
3
2
Predecessor
/
suc-
cessor
3
4
1
5
4
3
5
1
1
3