Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
595
4
4.8.3.21 Description of the Parameters
120.1
Status
Status of the homing.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Rea
d
on
ly
St
o
ra
g
e
DS Su
ppo
rt
Cyc
lic W
rite
120.1
Status
DWORD 0x0
0xFFFFFFFF 0x0
1:1
X
120.2
Mode
UINT
0x0
0xFFFF
0x0
1:1
X
120.3
Home position
UDINT
0x0
0xFFFFFFFF 0x00020000
Inc
1:1
X
120.4
Homing method
INT
-10
35
1
1:1
X
X
120.5
Homing speed
UDINT
1
65535
500
Inc/ms 1:1
X
120.6
Homing final speed
UDINT
1
65535
10
Inc/ms 1:1
X
120.7
Homing acceleration
UDINT
7
65535
200
Inc/
ms²
100:1
X
120.8
Homing deceleration
UDINT
7
65535
200
Inc/
ms²
100:1
X
120.9
Homing maximum jerk
UDINT
7
65535
25
Inc/
ms³
100:1
X
120.10
Homing encoder offset
UINT
0x0
0xFFFF
0x0
Inc
1:1
X
120.11
Homing blocking time
UINT
1
65535
100
s
100:1
X
120.12
Homing torque current limit
UINT
0
10000
2500
%
100:1
X
120.13
Output speed set value
DINT
-65535
65535
0
Inc/ms 1:1
X
120.14
Output acceleration set value DINT
-65535
65535
0
Inc/
ms²
100:1
X
120.15
Encoder angle at reference
switch
UDINT
0
0xFFFFFFFF 0
1:1
X
120.16
Homing max. position delta
to zero pulse
DINT
0
0x7FFFFFFF
0
Inc
1:1
X
X
120.17
Command
UDINT
0
1
0
1:1
Bit-no.
Meaning
0
1: Homing is switched on
1
1: Homing completed successfully
2
Acknowledgment for the "Set home position" command
3
Reserved
4
1: Speed set value at the output is zero
5
Reserved
6
1: Speed is limited to maximum speed (refer to
Speed limit and
Max speed mech.)