Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
582
4.8
118.20
Modulo value
The range of modulo values will be determined for the modulo positioning modes with this
parameter. A change of the parameter is only effective after a previous controller inhibit.
Details to module positioning see
Positioning target mode.
118.21
Positioning duration
In this parameter the duration of the last started positioning is shown. During a running
positioning the parameter indicates the actual positioning time.
The measurement starts with the start of the positioning. Measurement ends, if parameter
Output position set value reaches its target position. This is the case if param-
eter
Status messages signals in bit 4 "Speed set value = 0". This means only
the duration of the set value setting is measured.
The additional time for the parameters
Position actual value,
ing window and
Positioning window time to reach the target position is not con-
sidered.
The measurement is stopped with the Stop command as soon as parameter
Status messages in bit 4 "Speed set value = 0". The measurement is continued when the
stop command is cleared.
5
Positioning jerk
Refer to
Positioning Jerk
6
Looping time
Refer to
Positioning Smoothing Time
7
Relative target position
Refer to
Positioning Relative Target
Position
Index
Element
Description of elements