Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
519
4
4.7.6.3 Description of the Flux Controller parameters
146.10
Kp flux controller
Proportional gain of the flux controller.
146.11
Tn flux controller
Reset time of the flux controller [ms]
146.12
Limit magnetizing current
Limitation of the flux controller’s output [A]
146.15
Actual flux current
Flux current [A]
Display of the actual value of the rotor magnetizing current. The value is evaluated from
the actual flux value and the flux-current characteristic.
146.18
Integral term flux controller
Integral term of the flux controller