4.5
4.5.4
Error Management
The error messages and warnings of the drive are displayed in a central error memory
(
Error Information). This parameter is an array with 20 elements. Both error
messages and warnings are displayed in this array parameter.
Certain additional information is displayed at any error as e.g. the timestamp when the
error was messaged and reset.
The drive response to an error is configurable. Though the response to each error can be
set separately (see parameter
). The following responses are possible:
According to the error code not all error responses are possible. For example the pulses
are blocked at certain errors at once. Another response is not adjustable for such errors.
4.5.4.1 Parameter overview
Function block:
FbInfoMgr [100]
Error response
Description
No error message
The error will not be messaged.
No error response
The error is messaged but there is no response of the drive
(e.g. pulse block).
Pulse block
The pulses are locked and the drive goes in the failure state.
Stop at current limit
The drive is stopped at current limit. Afterwards the pulses
are locked and the drive goes in the failure state.
Stop (RFG-Quickstop
time)
The drive is stopped at the quick stop ramp. Afterwards the
pulses are locked and the drive goes in the failure state.
Stop (RFG-Ramp-down
time)
The drive is stopped at ramp down of the ramp function gen-
erator (Parameter 110.x). Afterwards the pulses are locked
and the drive goes in the failure state.
Return motion
The drive positions to an adjustable position. Afterwards the
pulses are locked and the drive goes in the failure state.
Controlled stop
The drive is braked at the ramp for the controlled stop. After-
wards the pulses are locked and the drive goes in the failure
state.
SS1 stop
The drive is braked at the ramp for the SS1 stop. Afterwards
the pulses are locked and the drive goes in the failure state.