Management
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
380
4.5
4.5.3.3 ProDrive Brake Management
Figure 130:
ProDrive Brake management
4.5.3.4 Parameter overview
Functional block:
FbBrakeMgr [134]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
on
ly
St
o
ra
g
e
D
S
Su
pp
or
t
Cyclic W
rite
134.1
Mode
DWORD 0
0xFFFFFFFF 0x22
1:1
X
134.2
Status
DWORD 0
0xFFFFFFFF 0
1:1
X
134.3
Control automatic
DWORD 0
0xFFFFFFFF 0
1:1
X
134.4
Command
WORD
0
0xFFFF
0
1:1
X
134.5
Torque limit
FLOAT
-1.00E+06
1.00E+06
0
Nm
1:1
X
X
134.6
Speed limit
FLOAT
0
1.00E+06
90
Grad/s 1:1
X
134.7
Timeout check-back signal
UINT
0
1000
1000
ms
1:1
X
134.8
Pulse inhibit delay
UINT
0
1000
500
ms
1:1
X
134.9
Start of motion delay
UINT
0
1000
500
ms
1:1
X
134.10
Opening delay
UINT
0
1000
0
ms
1:1
X