4.5.2.4 Delivered state
When delivered, only Data Set 1 is created. The other data sets DS 2 to DS 7 are deleted.
The active data set (DS 0) is Data Set 1. All parameters have their standard values.
Switching to another data set is not possible.
After the device is configured, the parameters in the device should be saved. If an error
occurs while saving (e.g. as a result of switching off the device during the programming
procedure), the device writes the standard values (default setting) to the parameters
when switched on again.
4.5.2.5 Switch-On behavior
After the b maXX
®
is switched on, all parameters are loaded with the stored data. The
device activates Data Set 1. Unconfigured data sets are set to default values.
4.5.2.6 Changing, loading, copying and storing parameters
Changes to parameter values (e.g. by ProDrive or via a Fieldbus) only affect the device's
working memory. If changes are also to be preserved after the next switch-on of the de-
vice, the parameters must be explicitly stored in the device. All the parameters in all the
created data sets are always stored.
With the aid of data set commands, the values of parameters in created data sets can be
loaded individually or completely into the working memory.
The data set copy function permits copying of the parameter values from a created source
data set to a different target data set. If the target data set has not been created yet, it will
be automatically created by the device. If the target data set has already been created,
the original parameter values will be overwritten.
Using the ProDrive Up/Download function on the "Data Set Management" page, param-
eters can also be saved to a PC data storage medium or written back to the device.
4.5.2.7 Identification of parameter set and data sets
There is the parameter
for identifying of the complete parameter set for a de-
vice.
For identifying individual data sets the following parameter are available:
Parameter
Data Type
Meaning
Data Set Name
STRING
Freely selectable text name for the data set
Data Set
Identification Number
UDINT
You can assign each data set (DS 1 to DS 7)
a unique number from 0 to 4294967295
here