Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
296
4.4
154.3
Lower speed threshold
Lower speed limit (speed limit for the left-hand sided switching threshold)
154.4
Upper speed threshold
Upper speed limit (speed limit for the right-hand sided switching threshold)
154.5
Output value 1
Connected friction compensation value for
Speed < Lower speed limit
154.6
Output value 2
Connected friction compensation value for
Lower speed limit
Speed < Upper speed limit
Effective only if connection „Three-point with hysteresis and dead zone“ (
Bit 2…1 = 00).
154.7
Output value 3
Connected friction compensation value for
Speed > Upper speed limit
154.8
Friction compensation actual output value
Connected friction compensation value at the moment.
154.9
Hysteresis speed threshold
Hysteresis for connection „Three-point with hysteresis and dead zone“ (
Bit 2…1 = 00), otherwise not effective.
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......