4.4
124.16
Encoder 1 trigger zero pulse neg. edge angle
Angle Encoder 1 with triggering of measurement through falling edge of Zero Pulse of En-
coder 1.
124.30
DS402 mode
to
.
Source and division of revolutions and angle.
NOTE!
for the DS402 touch probe 1 and 2 must
not
set the same source
Bit
Meaning
0
1: Switch on DS402 touch probe
Start calculation of the combined measured values
to
and if necessary
The respective source is selected in bits 16 … 23.
Configuration/scaling of the combined measured values see bits 2 ... 1.
Attention:
The respective channel in
Configuration mode must be activated!
0: Switch off
2 ... 1
Configuration/scaling of the combined measured values
:
00: Configuration corresponding to bits 4 … 9
01: Calculation with Factor Group (
)
1)
10: Modulo actual position value
2)
11: Reserved
3
Reserved