Asynchronous Motor
The asynchronous motor is operated with a temperature adapter and a slip set point. The
slip is calculated from the temperature-independent slip frequency, the I
d
-current actual
value and the flux actual value.
4.4.4.1 ProDrive Asynchronous Motor
Figure 74:
ProDrive Asynchronous Motor
4.4.4.2 Lh-characteristic
BM3300 can consider a non-linear Lh-characteristic for motor control. This can be en-
tered manually or can be identified in idle mode:
Manual input
m
Lh dependent on magnetizing current
m
Flux dependent on magnetizing current