![Baumuller b maXX BM1000 Скачать руководство пользователя страница 120](http://html.mh-extra.com/html/baumuller/b-maxx-bm1000/b-maxx-bm1000_manual_2711384120.webp)
Chopper units and braking resistors
Manual
b maXX
®
BM1000
Document No. 5.07003.04
Baumüller Nürnberg GmbH
120
B.1
B.1.1
Select a chopper unit /braking resistor
- in progress -
for further information please contact your nearest Baumüller representative.
NOTE
m
Please select the brake unit and/or braking resistor according to the table.
m
If damage to the device or other equipment is due to the fact that the braking resistors and
the braking resistors in use are not provided by Baumüller, the warranty will be void.
m
Take into consideration the safety of the environment when installing the braking resistors.
m
If the minimum resistance value is to be utilized, consult local dealers for the calculation of
the power in Watt.
m
Please select thermal relay trip contact to prevent resistor over load. Use the contact to
switch power off to the device!
m
When using more than 2 chopper units, equivalent resistor value of parallel brake unit can't
be less than the value in the column „Minimum equivalent resistor value for each device“
(see table below).
m
Please read the wiring information in the user manual of the brake unit thoroughly prior to
installation and operation.
V
o
lt
age
Device
Appli-
cable
motor
kW
Full
load
torque
Nm
Resistor value
spec for each
device
Chopper unit
model and
quantity
Braking resis-
tors
model and
quantity
Braking
torque
10 % ED
Min. equiva-
lent resistor
value for
each device
Typical
thermal
overload
relay value
230V se
ries
BM1211
0.2
0.110
200 W 250
Ω
BM1-BTE-23
1
R250-200-20
1
320
200
Ω
2 A
BM1212
0.4
0.216
200 W 250
Ω
BM1-BTE-23
1
R250-200-20
1
170
100
Ω
2 A
BM1213
0.75
0.427
200 W 150
Ω
BM1-BTE-23
1
R150-200-20
1
140
80
Ω
2 A
BM1224
1.5
0.849
300 W 85
Ω
internal
125
40
Ω
BM1225
2.2
1.262
450 W 60
Ω
internal
120
40
Ω
460V series
BM1412
0.4
0.216
300 W 400
Ω
BM1-BTE-46
1
R400-300-20
1
400
400
Ω
1 A
BM1413
0.75
0.427
300 W 400
Ω
BM1-BTE-46
1
R400-300-20
1
200
200
Ω
1 A
BM1414
1.5
0.849
400 W 300
Ω
BM1-BTE-46
1
R150-200-20
2
140
160
Ω
BM1425
2.2
1.262
600 W 200
Ω
internal
R400-300-20
2
140
140
Ω
BM1426
3.7
2.080
750 W 140
Ω
internal
125
96
Ω
BM1437
5.5
3.111
1100 W 96
Ω
internal
120
96
Ω
BM1438
7.5
4.148
1500 W 69
Ω
internal
125
69
Ω
BM1439
11
6.186
2000 W 53
Ω
internal
108
53
Ω
Содержание b maXX BM1000
Страница 1: ...E 5 07003 04 Manual b maXX BM1000 Basic unit ...
Страница 8: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 8 of 174 Table of contents ...
Страница 42: ...Mounting instructions Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 42 of 174 5 6 ...
Страница 100: ...Affecting other machines Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 100 of 174 8 9 ...
Страница 108: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 108 of 174 ...
Страница 112: ...Recommissioning Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 112 of 174 11 6 ...
Страница 116: ...Recycling plants offices Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 116 of 174 12 4 ...
Страница 118: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 118 of 174 A ...
Страница 140: ...UL certification Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 140 of 174 C 5 ...
Страница 148: ...Fire fighting appliances Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 148 of 174 D 7 ...
Страница 158: ...CANopen display functions Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 158 of 174 E 6 ...
Страница 172: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 172 of 174 Index ...
Страница 174: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Страница 175: ......