![Baumuller b maXX 5500 Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/baumuller/b-maxx-5500/b-maxx-5500_instruction-handbook-manual_2711410053.webp)
Technical Data
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
53
3
3.3.4
Required environmental conditions
Transport temperature range
- 25 °C to + 70 °C
Transport climatic category
EN 60721-3-2
2 K 3
Storage temperature range
- 25 °C to + 55 °C
Storage climatic class
EN 60721-3-1
1 K 4
Operation environment
Industrial system
1)
Category C2 according EN61800-3
for operation in Second Environment
Operation temperature range
Min. 5 °C to max. 55 °C
(with derating above 40 °C)
3)
Operation climatic class
EN 60721-3-3
3 K 3
Operating altitude
Up to 4000 m above MSL,
except BM551X, BM5526, BM5527 up to 2000 m
(with derating above 1000 m)
2)
Humidity (operation)
EN 60721-3-3
Relative humidity: 5 % to 85 % no condensation
and
absolute humidity: 1 g/m
3
to 25 g/m
3
Ionizing and non-ionizing radiation
< measurable range
Vibration, shock and repetitive shock
EN 61800-5-1, section 5.2.6.4 Vibration test
Max. 0.5 g during operation
Degree of pollution
EN 61800-5-1, table 6, Tab. 2
2
1)
For the operation in an environment of category C2 according to IEC 61800-3:2012, additional measures may be required.The manu-
facturer of the installation / user must provide the following evidence in this case: The additional measures are effective. The specified
limit values of category C2, which are described in IEC 61800-3, are complied with.
2)
Refer to correction factors at environmental conditions,
3)
Refer to correction factors at environmental conditions,
NOTICE!
Normally, non-conductive pollution occurs. Conductive pollution is unacceptable.
Conductive pollution can lead to the destruction of the device. The customer is re-
sponsible for destructions, which were caused by pollution due to conductive materi-
als or components.