![Baumuller b maXX 5500 Скачать руководство пользователя страница 161](http://html.mh-extra.com/html/baumuller/b-maxx-5500/b-maxx-5500_instruction-handbook-manual_2711410161.webp)
Installation
Instruction handbook
b maXX
BM5500, BM5600, BM5700
Document No.: 5.13008.10
161
7
7.2
Voltage test
7.3
Demands on the power supply
For all important data, refer to
Requirements to the energy supply / supply system
Minor deviations from requirements in the power supply can lead to malfunctioning of the
device. If the power supply deviates too much from the requirements, the device can be
destroyed.
The devices may only be operated in industrial networks.
The destruction of the device can cause personal injury.
DANGER!
Risk of fatal injury from electrical current!
During the routine test of these devices, a voltage test is performed by Baumüller
Nürnberg GmbH in accordance with EN 61800-5-1, Section 5.2.3.2. It is thus unnec-
essary for the customer to do this.
Therefore:
m
Subsequent tests of the devices using high voltages may only be performed by
Baumüller Nürnberg GmbH.
m
Disconnect the converter from the system during high-voltage testing!
DANGER!
Risk of fatal injury from electrical current!
If the requirements for the power supply are not complied, the device can be dam-
aged or destroyed, thereby greatly endangering individuals.
Therefore:
m
Prior to installation, ensure that the demands for power supply have been fulfilled.
NOTE!
Pay attention to connect the basic units without load resistor (BM5XXX-X
T
/
BM5XXX-X
I
/BM5XXX-X
G
to a power supply with
clockwise rotating field
.
Connection to a power supply with clockwise rotating field is
not required
for
BM5XXX-X
R
/BM5XXX-X
S
/BM5XXX-X
W
,.