Requirements for the motor temperature sensors
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
140
7.11
Installation of toroidal cores
h
The three phases
without shielding
and
without PE
must be lead through the cores.
The cores must be installed and attached near the motor connection of the
5000.
h
When using toroidal cores it is further recommended to use current isolated bearings
on the nondrive end for synchronous/asynchronous main drives sizes 180 and higher.
Figure 62:
Mounting - single ring core
Figure 63:
Mounting - several ring cores
7.11 Requirements for the motor temperature sensors
To protect the motor against impermissible overheating, a motor temperature sensor can
be connected to the
b maXX
device. The device switches off of the motor when a settable
threshold temperature has been exceeded.
Type
Additional requirements:
Isolation
KTY84/PT1000
-
SELV/PELV
MSKL
1)
(PTC)
R = 1 k
at T
Protection
, I
max
< 2 mA
SELV/PELV
1)
Motor protection thermistor (PTC) as per DIN 44080-082
NOTE!
The motor temperature sensor should be installed in such a manner that „electrically
protective separation“ is ensured. The motor temperature sensors integrated into
Baumüller motors meet these requirements. If third-party motors are connected, the
operating company must ensure that the temperature sensors used in the motor of a
third-party manufacturer motor comply with the „electrically protective separation“
function.
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......