Procedure of the commissioning
Instruction handbook
b maXX
(BM4-F-)DIO/FIO-XX (Digital IO module)
Document No. 5.01046.06
Baumüller Nürnberg GmbH
48
8.2
10
Check whether the text: „
module not existent
“ is displayed. In this case, the module
was not recognized.
Figure 14:
Module not existent
m
Only if there is
no
message under the scale, the
Digital IO module
is recognized
properly and can be used.
m
If the
Digital IO module
is not recognized, then switch off the device and check the
assembly/installation. After having removed all errors, restart the device for check-
ing whether the plug-in module gets recognized properly now.
m
If the
Digital IO module
is not recognized yet, then it is defective or the controller/
controller slot. In that case, contact Baumüller Nürnberg GmbH for replacement.
m
Once the
Digital IO module
has been recognized properly following with
Testing of the Digital IO module
NOTICE!
Notice electrostatic discharge
The
Digital IO module
or the
b maXX
4000
may get damaged if the module is
plugged or pulled out when the
b maXX
4000
is energized.
If the plug-in module has still to be pulled out from the
b maXX
4000
due to an exter-
nal action, switch off the
b maXX
4000
.
Try then to push in the
BM4-F-DIO/FIO-XX
again as described in the chapter