Technical Data
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
33
3
1-phase operation
below rated
supply voltage
The rated voltage is 3 x 400 V
At smaller supply voltages the output power of the device reduces.
3.3.6.4 DC-link voltage
Output cur
rent
[%
]
DC-link voltage [V]
At DC-link voltages above the rated supply voltage the output current must be reduced at
constant output power.
Figure 12:
Output current dependent on DC-link voltage
Output
power devic
e
P
rated
Continuous operation
permitted
Supply voltage
Figure 11:
Output power dependent on supply voltage
If the output current is multiplied with the output voltage, the output power of the device is pro-
vided.
S
output
= U
output
x I
output
x
3
Содержание b maXX 3000