11.1
11.1.10.5 Connecting cable for sine/square-wave incremental encoder
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1
Utilize the following materials:
m
Cable: Li9YC3x2x0.25-Li9Y3x2x0,25-Li9Y C11Y 1x2x0.34GN. Two cable pairs are
not needed and also not connected.
m
High-density D-sub connector: 26-pin, male
m
Round connector: 12-pin, female (e.g. from Interconnectron)
2
Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 75:
Connecting cable for sine/square wave incremental encoder
5000_1
103_rev01_int.cdr
2
1
4
5
6
8
9
12
11
17
18
7
12
10
5
6
8
3
4
2
11
7
9
1
Æ
0.34 mm
Æ
0.34 mm
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not functionally operable and could
lead to defects, both in the encoder module and the encoder!
Содержание b maXX 3000
Страница 67: ...Design and Function Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 67 of 218 4 ...
Страница 208: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 208 of 218 A ...
Страница 209: ...209 of 218 Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 212: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 212 of 218 ...
Страница 218: ...Instruction handbook b maXX BM3000 BM3200 BM3300 Document no 5 11018 11 Baumüller Nürnberg GmbH 218 of 218 Notes ...
Страница 219: ......