![Baumuller b maXX 1000 Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/baumuller/b-maxx-1000/b-maxx-1000_parameter-manual_2711401074.webp)
Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
74
4.3
P1079
This parameter displays the warning code.
P1079
Warnung Code
0 to 65535
-
Warning code
0
A
BM_u_WarningCode
1:1
Value
Meaning
7
Communication error Modbus (cE10)
8
Motor loading exceed (oL2)
9
Warning, wareform by H2100hi byte (AUE)
10
Under current (Uc)
11
Warning, PU Keypad Copy parameter operation error (SE1)
12
Warning, PU Keypad Copy parameter save error (SE2)
13
Warning, Motor PTC temperature warning (PtC2)
14
PG loss warn (PG_WARN)
15
Warning, IO PID feedback error (FbE)
16
Warning, IO PU keypad copying (SAvE)
23
IO COM1 comm time out (PE10)
24
ADDA card break off (AoFF)
25
Lower than standard voltage (Lv)
26
Control broad ACI (current) loss (Aerr)
27
Base-block (bb)
33
CANopen SDO Time out (CSdo)
34
CANopen SDO buffer overflow (CSbF)
36
Can Boot up fault (CbtU)
50
Error count for CAN detect (cc01)
51
SYNC fault(cc03)
52
Communication error USB card (UbCd)
53
Error protocol of CANOPEN (cPt2)
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......