P1010
Free selectable identification number of saved parameter set. For customer to identify the
version of the parameter setting for different data sets.
P1070
The relationship between the motor rotation and PG input is illustrated below:
P1071
A pulse generator PG is used as a sensor that provides a feedback signal of the motor
speed. This parameter defines the number of pulses for each cycle of the PG control (1
pole pair max. 20000 Inc.)
P1010
Datensatz Identifikations-Nummer
0 to 65535
EE
Data set ID
0
STOP
BM_u_RecordId
1:1
P1070
PG Funktionsauswahl
0 to 3
EE
PG function selection (enable card)
0
STOP
BM_PGFunctionSelection
1:1
-
Value
Meaning
0
Disable Pulse generator PG
1
Single phase
2
Forward/counter clockwise rotation
3
Reverse/clockwise rotation
= 2
= 3
P1071
PG Strichzahl Bereich
0 to 20000 Inc
EE
PG pulse range
600 Inc
STOP
BM_u_PGPulseRange
1:1
-
Содержание b maXX 1000
Страница 1: ...E 5 07004 03 b maXX 1000 Parameter manual ...
Страница 65: ...Parameter Parameter manual b maXX 1000 Document no 5 07004 03 65 of 208 4 Figure 18 Base block speed search ...
Страница 164: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 164 of 208 A ...
Страница 208: ...Parameter manual b maXX 1000 Document no 5 07004 03 Baumüller Nürnberg GmbH 208 of 208 Notes ...
Страница 209: ......