Fault detection
Instruction handbook
b maXX
(BM4-F-)AIO-XX (Analog IO module)
Document No.: 5.01045.08
Baumüller Nürnberg GmbH
66
10.2
h
Select „Drive management“
The window „Drive manager“ opens, see below with an exemplary (error) message.
Before the communication between controller and PC/laptop is started, the messages in
this list have been arranged in numerical order. The newly occurring messages are added
to the end of the list, when communication is active.
Figure 26:
Drive manager ProDrive
NOTE
If you are not able to start the motor, although the red LED H4 is not lighting up and
although the LED H2 is lighting up green, check the parameterization of the
b maXX
4000 with the parameter list in ProDrive.
Error possibilities are e. g.: torque limit = 0 has been set or notch position is not cor-
rect (also see parameter manual
b maXX
4000).
If no LEDs are lighting up on the front side of the device, check the 24V supply.