GENERATOR USER'S MANUAL

MODEL: BM X20i 

Содержание BM X20i

Страница 1: ...DIGITAL INVERTER GENERATOR USER S MANUAL MODEL BM X20i ...

Страница 2: ...ds scheduled maintenance keep in mind that your servicing dealer is specially trained in servicing your generators Pay special attention to statements preceded by the following words You can be killed or seriously hurt if you don t following instructions You can be hurt if you don t follow instructions ATTENTION The generator is a potential of electrical shock if misused Do not expose the generato...

Страница 3: ...ATION 5 4 PRE OPERATION CHECK 7 5 STARTING THE ENGINE 8 6 GROUND SYSTEM 9 7 GENERATOR USE 10 AC APPLICITIONS 11 AC OPERATION 12 HIGH ALTITUDE OPERATION 12 8 STOPPING THE ENGINE 13 9 MAINTENANCE 13 10 TRANSPORTING STORAGE 15 11 TROUBLE SHOOTING 16 12 ELECTRICAL WIRING DIAGRAM 18 ...

Страница 4: ...cant FB grade 2 stroke oil Ratio of fuel lubricant 50 1 Rated AC frequency 50Hz 60Hz 50Hz Rated AC voltage 220v 230v 110v 240v Rated AC current 5 5A 7 2A 5 0A Rated AC output 1200VA Surge AC output 2000VA Total harmonic distortion 3 Power factor cos 1 0 Frequency stability 0 1Hz Voltage stability 4V Operating noise level 60Db 7m Fuel consumption g kw h 550 at full load Continuous operation at 1 2 ...

Страница 5: ...FETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury Read them carefully If a label comes off or becomes hard to read contact your generator dealer for a replacement ...

Страница 6: ... do not start or run the engine until all leaks are fixed After every use place the engine switch in the OFF position and close the fuel tap Running petrol engines in confined areas CAN KILL IN MINUTES Engine exhaust fumes contain carbon monoxide a deadly gas that you cannot smell or see NEVER run a petrol engine in confined areas EVEN IF windows and doors are open ONLY run petrol engines OUTDOORS...

Страница 7: ... cause loss of consciousness and may lead to death To keep exhaust gas from accumulating provide adequate ventilation Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused Fire and Burn Hazards The exhaust system gets hot enough to ignite some materials Keep the generator at least 1 meter 3 away from buildings and other equipment d...

Страница 8: ...ons of dirt and dust A dirty filter reduces engine efficiency and power output If dirty clean the air filter element in warm water and mild detergent then dry it Place a few drops of oil it then squeeze is to distribute the oil before re installing it Air filter appearances may vary to that pictured ENGINE SWITCH To run and stop the engine OFF O To stop the engine ON I To start and run the engine ...

Страница 9: ...er cord until you feel it engage with the motor then pull rapidly Note If excessive petrol flooding causes starting difficulty remove the spark plug close the fuel tap place the engine switch in the OFF position place the choke in the RUN or HOT position and fully open the throttle then pull the starter several times Afterward re install the spark plug and follow the normal starting procedure Do n...

Страница 10: ...consult a qualified electrician electrical inspector or electrical codes authority that apply to the intended use of the generator Output Indicator OVERLOAD ALARM INDICATOR If the generator is overloaded in excess of 1250VA or a short circuit occurs in a connected appliance the indicator light will become red After approximately 4 seconds current to the connected appliances is shut off When under ...

Страница 11: ...ly with all applicable laws and electrical codes Improper connections to a building electrical system can allow electrical current from the generator to feedback into the utility lines Such feedback may electrocute utility company workers or others who contact the lines during a power outage and the generator may explode burn or cause fires when utility power is restored Consult the utility compan...

Страница 12: ...liance does not exceed that of the generator Never exceed the maximum power rating of the generator Power levels at the rated maximum 1250VA should be used for no more than 15 minutes continuously Substantial overloading will bypass the AC circuit protector Exceeding the time limit for maximum power operation will shorten the service life of the generator Limit operation requiring maximum power to...

Страница 13: ...gate the problem Determine if the cause is a short circuit in a connected appliance or an overload Correct the problem and restart the generator HIGH ALTITUDE OPERATION High altitude performance can be improved by specific modifications to the carburetor If you always operate your generator at altitudes above 1500 meters 5000 have your servicing dealer perform this carburetor modification This eng...

Страница 14: ...lean or replace as necessary Clean the fuel strainer 3 Check after running 50 hours Tighten the cylinder head nuts Clean any accumulated carbon both in the combustion chamber and in the exhaust of the cylinder Clean any accumulated carbon on the spark plug and adjust the gap to 0 6mm Clean any accumulated carbon both in the intake and in the exhaust Safety Precautions Make sure the engine is off b...

Страница 15: ...ptoms have your engine inspected and repaired by your servicing dealer Hard starting or stalling after starting Rough idle Misfiring or backfiring under load Afterburning backfiring Black exhaust smoke or high fuel consumption NOTE Emission related items 1 Service more frequently when used in dusty areas 2 These items should be serviced by your servicing dealer unless the owner has the proper tool...

Страница 16: ...ly close the choke 2 Remove the spark plug and pour approximately 30ml of engine oil into the spark plug hole then slowly draw the starter several times 3 Bring the piston to the top dead center the install the spark plug 4 Use a soft cloth with a little engine oil to clean the surface of the engine then store the unit in a dry place 0 50 0 70mm SEALING WASHER SPARK PLUG SERVICE In order to servic...

Страница 17: ... tank and carburettor and replace fuel 3 Engine runs but lacks power Blocked air filter Clean and or replace Accumulated carbon in the exhaust Clean Piston piston rings and cylinder worn Replace parts as required Fuel strainer blocked Clean Leak in air intake or combustion chamber not sealed Repair 4 Engine stops suddenly when running Run out of petrol Refuel The spark plug has accumulated carbon ...

Страница 18: ...cator light ON Is the overload indicator on Take generator to an authorized service center Check the electrical appliance or equipment for defects Replace the electrical appliance or have it repaired Restart the generator NO YES NO NO DEFECTS DEFECTS ...

Страница 19: ...18 ELECTRICAL WIRING DIAGRAM BM X20i ...

Страница 20: ...en access to the product The product has been supplied by a general merchandise retailer that may not be familiar with your specific applic ation or your description of the application Be sure to attain third party approval for your application from a qualified specialist before use regardless of prior assurances by the retailer or its representatives This product is not intended for use where fai...