9.6 Process Interface
9.6.1 Digital IOs
User Definable Inputs
9.6.1.1
The wiring of these input connectors is left to the user.
Sole exception is the compliance with predetermined high and low levels (0 .. 4,5V low,
11 .. 30V high).
The defined signals will have no direct effect, but can be analyzed and processed on the
software side and used for controlling the camera.
The employment of a so called "IO matrix" offers the possibility of selecting the signal and
the state to be processed.
On the software side the input signals are named "Trigger", "Timer" and "LineOut 1..3".
(Input) Line 1
Trigger
Timer
LineOut 1
LineOut 2
LineOut 3
state high
state low
IO Matrix
state selection
(inverter)
signal selection
(software side)
1
2
3
4
5 6
7
8
Figure 31 ►
IO matrix of the
Baumer VisiLine on in-
put side.