Baumer SensControl Скачать руководство пользователя страница 1

V1 | 8/12/2021

EN-US

Operating Manual

SensControl

Wireless IO-Link Master and App

Содержание SensControl

Страница 1: ...V1 8 12 2021 EN US Operating Manual SensControl Wireless IO Link Master and App ...

Страница 2: ... 8 2 7 Dimension drawing connections and display elements 9 3 Commissioning 10 4 Operation 11 4 1 Switching the SensControl on off 11 4 2 Changing the operating mode master sniffing 11 4 3 Charging the battery 11 4 4 Operating the SensControl in sniffing mode 12 4 4 1 Connecting the SensControl sniffing mode 12 4 4 2 Activating sniffing mode 13 4 4 3 Reading the MicroSD card 13 4 5 Resetting to fa...

Страница 3: ...s are at the discretion of Baumer at all times The product is not intended for permanent installation in automation systems NOTICE The device can cause radio frequency interferences This is a device of class A This device can cause radio frequency interferences in residential areas In such cases the operator may be asked to carry out appropriate measures 1 2 Applicable documents n Operating Instru...

Страница 4: ... document Baumer 4 Operating Manual SensControl V1 1 5 Name plate The name plate can be found on the back of the SensControl Made in Germany 1 2 3 Ill 1 Name plate 1 Serial number 2 Device name 3 WLAN SSID ex works ...

Страница 5: ...ds in the SensControl app are forwarded to the IO Link device n Master mode is the mode in which the SensControl starts when it is switched on n As soon as an IO Link device is connected to the SensControl communication is estab lished between the IO Link device and the SensControl Communication is maintained as long as the IO Link device is connected 2 2 2 Sniffing mode n The SensControl tracks t...

Страница 6: ...rating in Master mode and the IO Link de vice has the status OPERATE Lights up red No IO Link device is connected or the status could not be changed to OPERATE No communication with the connected IO Link de vice is possible Flashing blue The SensControl is operating in sniffing mode Lights up blue The SensControl is operating in sniffing mode and is waiting for a STARTUP command from the connected...

Страница 7: ...ailable in the Apple App Store and Google Play Store Ill 3 SensControl app Roles The SensControl app distinguishes between 3 roles that have different permissions Observer Maintainer Specialist Authorization Observer Maintainer Specialist Identification Read out identification data X X X Parameter Parameterize IO Link device X X Diagnosis Read out diagnostic data X Also see about this 2 Operation ...

Страница 8: ... SensControl provides up to 350 mA for the IO Link device If the IO Link device to be used requires more power a 24 V power supply unit can be con nected to the connection for the IO Link master in order to supply the IO Link device directly with power Also see about this 2 Charging the battery 11 2 6 Connection assignment Ill 4 Connections on the SensControl Connection for IO Link master Master 1...

Страница 9: ...Baumer Description 2 V1 SensControl Operating Manual 9 2 7 Dimension drawing connections and display elements Ill 5 Dimension drawing connections and display elements ...

Страница 10: ...ntrol c Start the SensControl app on your smartphone tablet d Activate Bluetooth or WLAN on your smartphone tablet and wait until the SensControl ap pears in the connection view The Bluetooth connection is the most convenient way to work e Tap on the SensControl that is found Result ü The connection between the SensControl and IO Link device is established ü The SensControl automatically downloads...

Страница 11: ...Control is working in sniffing mode ü LED 2 lights up yellow The SensControl cannot start sniffing mode because the MicroSD card cannot be used no MicroSD card is inserted or no storage space is available on the MicroSD card or the first partition is not FAT32 formatted ü LED 2 lights up green The SensControl is operating in master mode 4 3 Charging the battery INFO When a power supply is connecte...

Страница 12: ...Sniffing mode is set up with other devices analogously Set up sniffing mode in the following order 1 Connect the SensControl 2 Activate sniffing mode Afterwards you can read out the MicroSD card to view the data Also see about this 2 Connecting the SensControl sniffing mode 12 2 Activating sniffing mode 13 2 Reading the MicroSD card 13 4 4 1 Connecting the SensControl sniffing mode 1 2 3 1 Anschlu...

Страница 13: ...sniffing process the SensControl saves a continuous CSV file on the MicroSD card c Open the desired CSV file Interpretation of the CSV file example Code in CSV Time since power on µs Data direction I Sent data to the end of the line II 792624101 0 a2 00 792624101 0 a200 792624218 1 06 1e a2 00 06 1e a3 11 2b 1b a4 33 11 28 a5 22 c3 2d 792624218 1 06 1e a2 00 06 1e a3 11 2b 1b a4 33 11 28 a5 22 c3 ...

Страница 14: ...ng the IODD source Instruction a Tap the gear icon in the upper right corner ü The Settings page opens b Tap IODD Repository URL c Select the desired source URL from which the IODD of the IO Link device is to be down loaded NOTICE The SensControl automatically downloads the IODD from the URL set here as soon as you connect the IO Link device to the SensControl Alternatively you can define the IODD...

Страница 15: ...lly recommended for submenu items that you need regularly In the following the creation of a fa vorite is described using the example of the submenu item Vendor Name Instruction a Navigate to the desired submenu item In our example Identification Vendor Name b Tap the asterisk on the right of the submenu item Result ü The submenu item is saved in the list of favorites ...

Страница 16: ...ice connected to the SensControl The following is an example of how to parameterize the switch point SP1 for an inductive distance sensor from Baumer Condition ð You are registered with the role Specialist a On the start page tap Parameters ü The Parameter page opens listing the parameters that can be set for the sensor b Tap SSC1 Configuration ü The SSC1 Configuration page opens ...

Страница 17: ...Baumer Operation 4 V1 SensControl Operating Manual 17 c Tap Setpoints ü The Setpoints page opens d Tap SSC1 Param ü The SSC1 Param page opens ...

Страница 18: ...eration Baumer 18 Operating Manual SensControl V1 e Tap on SP1 ü The SP1 page opens f Use the slider bar to set the desired value for SP1 1 and confirm with Apply 2 1 2 Result ü The parameter for SP1 is set ...

Страница 19: ... Smart n WLAN Supported standards n IO Link versions 1 0 and 1 1 n IODD versions 1 0 1 and 1 1 Power supply n Choice of Integrated USB port IO Link master Integrated battery n With battery operation Max current IO Link device 350 mA Operating time more than 3 h at 2 W Voltage IO Link device 24 V 20 Radio transmission output max n WLAN 18 dBm n Bluetooth Smart 2 dBm Standards n EN 55022 2010 Class ...

Страница 20: ...perating Manual SensControl V1 List of illustrations Ill 1 Name plate 4 Ill 2 Functionality of the SensControl 5 Ill 3 SensControl app 7 Ill 4 Connections on the SensControl 8 Ill 5 Dimension drawing connections and display elements 9 ...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...www baumer com worldwide ...

Отзывы: