Description
Baumer
10
Operating Manual
OM20/OM30 IO-Link | V2
3.3
Measurement field
INFO
The data for your sensor version can be found in the data sheet.
MR
Sdc
Sde
ZP
ZP
Zero position
MR
Measuring range
Sdc
Start of the measuring range
Sde
End of the measuring range
Measuring range (MR)
n
Region in which the measurement object must be present for the sensor to deliver reliable
measurement results.
n
Unwanted objects (objects not to be measured) in this region may lead to deviations in the
measurement results.
n
The limits of the measurement range (MR) are defined via the parameters
Start of the mea-
surement range (Sdc)
and
End of the measurement range (Sde)
.
Zero position (ZP)
n
In the factory settings, the zero point is located on the front of the sensor (ZP =
0 mm
). The
output consists of the distance between the front of the sensor and the measurement object.
n
The following values depend on the zero position:
▪ Output measured values
▪ Analog value
▪ Switching points
n
Capable of parameterization via:
▪ IO-Link
▪ Teach button