![Baumer O200 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/baumer/o200/o200_instruction-manual_2710746009.webp)
en_BA_O200_IO-Link_V1.docx
9/34
Baumer Electric AG
15.08.2018/
Frauenfeld, Switzerland
4
Parameter
4.1
System Commands
A factory reset of the sensor activates the default parameters as programmed in the factory. All parameters
changed by the user will be lost.
Parameter name
Short Description
Rights
Unit / Allowed
values
Standard command
Restore Factory Settings
wo
4.2
Measurement Data Channel (MDC)
4.2.1
Measurement Values
Parameter name
Short Description
Rights
Unit /
Allowed
values
Measurement
Value.Intensity
Intensity measuring value
(Only available for O200.R)
ro
0 … 32000
Measurement
Value.Quality Value
The quality value represents the excess gain
ration in %
100 = Exactly the amount of light needed for a
switching operation
200 = Twice the amount of light needed
O200.G, O200.S:
Quality = Strength of received light / Strength
required
O200.R:
Quality = Intensity value / SSC1 SP1
ro
0 … 32000