5.2
Static
By using teach commands, setpoint 1 and setpoint 2 (SP1 and SP2) can be set by placing the object at the
desired position and triggering the command. Which command is used in which order varies depending on
the active switching mode (Single-Point or Window) of the selected-teach channel and is explained in the
following sections.
Switching Mode
Teach Mode
Applicable
for
Result
Single Point
1-Point Teach
All
Defines SP1 by teach-in only one position and
adding a configurable offset to this
position/value.
O200.G:
Teaches the position of the object
SP1 = TP + TPO
O200.R:
Teaches the sensor hitting the reflector without
any object in between.
SP1 = TP * TPO
O200.S:
Teaches the reference/backgroundposition.
Single Point
2-Point Teach
O200.G
O200.R
Defines SP1 based on TP1 and TP2 for an
optimized switching behaviour.
O200.G:
Teaches the position of the object and of the
background.
SP1 = (TP1 + TP2) / 2
O200.R:
Teaches the sensor hitting the reflector with and
without an object in between
SP1 = sqrt(TP1 * TP2)
Window
Window
Teach
O200.G
Defines a window based on two positions