Local User Interface
Different parameters are available to configure the local user interface which means the indication LED and
the qTeach availability or qTeach mode (Xpress vs Xpert, static vs dynamic)
4.6.1
Local Teach Settings
Parameter name
Short Description
Rights
Unit / Allowed values
Teach Lock Settings.Teach Lock Time
This parameter is only applicable for the
qTeach – the teach-in by wire is not
affected / locked at any time.
Defines the time between
power up and qTeach
deactivation.
0:
qTeach never locked
1
– 120 min:
Accepted range
0xFF:
qTeach always
locked
Default: 5 min
rw
0
… 120 min
0xFF
Teach Mode Settings.Teach Mode
Defines the teach mode for
the qTeach and teach by
wire.
rw
Xpert Static
Xpress Static
Xpert Dynamic
Xpress Dynamic