en_BA_RR30_IO-Link_V0.23.docx
33/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
4.12.6
Tracking: slow
The “Tracking: slow - Profile” can be used for very slow or a not moving target. For good result the speed of
the target should be less < 0,01 m/s.
4.12.7
Tracking: standard
The Tracking “Tracking: Standard “-Profile should be selected when the objects are moving with a speed up
to a maximum speed of 1 m/s. In cases the profile will not work proper please select the slower or faster
version to test if an improvement can be achieved.
4.12.8
Tracking: fast
The Tracking “Tracking : Fast“-Profile should be selected when the object is moving with a speed of > 1 m/s
up to a maximum speed of 10 m/s. The maximum speed range depends on the characteristic of the objective
surface. For faster objects no tracking can be chosen. A good trackable surface can be detected at a higher
speed compared to a bad detectable target. In case the profile will not work proper please select the slower
version to test if an improvement can be achieved.
5
Diagnosis
In addition to solving the primary application, the evaluation of secondary data, such as temperature, supply
voltage or operating time, allows a predictive maintenance and thus optimum machine availability.
5.1
Device Status
Parameter name
Short Description
Rights
Unit / Allowed values
Device Status
Indicates if the sensor is
working properly
ro
- 0 = Device is OK
- 2 = Out of Specification
- 4 = Failure
Detailed Device Status
ro
5.2
Device Temperature
An integrated sensor allows to track the internal temperature of the radar.
Please be aware that the measured values are higher than the ambient temperature due to the internal
heating of the radar.
The temperature may also vary due to mounting conditions and the electric load connected at the output.
Parameter name
Short Description
Rights
Unit / Allowed values
Device Temperature Reset
Resets the device
temperature statistic
wo
Device Temperature.Current
Internal temperature of the
sensor
ro
Device Temperature.
Resettable
Min
Minimal measured internal
temperature of the sensor
(Resettable)
ro
Device Temperature.
Resettable
Max
Maximal measured internal
temperature of the sensor
(Resettable)
ro
Содержание IO-Link RR30