ELECTRICAL CONNECTION / TERMINAL SIGNIFICANCE
13/29
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN
5.
ELECTRICAL CONNECTION
5.1
Terminal significance
Ub
Voltage
supply
0V
Ground
A+
1)
Output signal channel 1
A−
1)
Output signal channel 1 inverted
B+
1)
Output signal channel 2 (offset by 90° to channel 1)
B−
1)
Output signal channel 2 inverted
R+
1)
Zero pulse (reference signal)
R−
1)
Zero pulse inverted
nE+ System OK+ / error output
nE− System OK− / error output inverted
PRE RESET (see also
DIR Rotating direction (see also
)
SP+
2)
DSL_OUT1 / speed switch (open collector* or solid state relay*)
SP−
2)
DSL_OUT2 / speed switch (0V* or solid state relay*)
SA
3)
RS485+ / programming interface
SB
3)
RS485− / programming interface
D+
SSI
data+
D− SSI data−
C+
SSI
clock+
C− SSI clock−
dnu Do not use
* Depending on version
1)
Additional output incremental (option)
2)
Speed switch (option)
3)
Programming interface (only PMG10P)
Содержание Hubner PMG10