MB107 - 11055718
Baumer_FS90_II_DE-EN (19A4)
18
Technical data
9
9
Technical data
9.1
Technical data - electrical ratings
•
Switching accuracy:
±4 % (Δn = 2 rpm/s)
≤ +20 % (Δn = 1500 rpm/s)
•
Switching deviation cw-ccw rotation: ≤3 %
•
Switching hysteresis:
~40 % of switching speed
•
Switching outputs:
1 output, speed control
•
Output switching capacity:
≤6 A / 230 VAC
≤1 A / 125 VDC
•
Minimum switching current:
50 mA
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approval:
CE
9.2
Technical data - mechanical design
•
Size (flange):
ø87 mm
•
Shaft type:
ø11 mm solid shaft
•
Flange:
EURO flange B10
•
Protection DIN EN 60529:
IP55
•
Speed (n):
≤1.25 · ns
•
Range of switching speed (ns):
850...4500 rpm (Δn = 2 rpm/s)
•
Operating torque:
≤2 Ncm
•
Rotor moment of inertia:
0.35 kgcm
2
•
Admitted shaft load:
≤150 N axial
≤250 N radial
•
Materials:
Housing: aluminium die-cast
Shaft: stainless steel
•
Operating temperature:
-40...+130 °C
•
Weight approx.:
900 g
•
Connection:
Terminal box
Test conditions for switching speed
a) Speed rise Δn = 2 rpm/s
b) Speed rise Δn = 1500 rpm/s
n
t
ns´
ns
a)
b)