6
|
Electrical installation
Baumer Hübner
26
Operating Manual
PMG10 & PMG10P CANopen | V1
6.2.3
Switching level additional output incremental (optional)
Switching level
TTL/RS422
TTL/HTL (Vin = Vout)
I
High/Low
≥ 2,5 V / ≤ 0,5 V
n
≥ 2,5 V / ≤ 0,5 V (TTL)
n
≥ Ub − 3 V / ≤ 1,5 V (HTL)
Transmission length
≤ 550 m bei 100 kHz
n
≤ 550 m bei 100 kHz (TTL)
n
≤ 350 m bei 100 kHz (HTL)
Output frequency
≤ 600 kHz
n
≤ 600 kHz (TTL)
n
≤ 350 kHz (HTL)
I
The TTL/HTL output (Vin = Vout) at the additional output II incremental is galvanically iso-
lated and requires a separate voltage supply.
Tab. 1:
Switching level additional output incremental (optional)
6.2.4
Programming interface (only for programmable variant)
Encoder parameters such as additional output, switch-off and switch-on speeds or also the
switching hysteresis can be changed and read out via connection SA and SB. The Z-PA.SDL1
WLAN adapter can be used for encoder access via web browser.
Also see about this
2
Z-PA.SDL.1 WLAN adapter: Programming device for HMG10P/PMG10P [
6.2.5
LED activity indicator
LED
red
green
INC1
No function
No function
INC2 (additional output incre-
mental
n
Undervoltage
n
Overload
n
Excess temperature
OK
Status
Internal error
OK
Speed
Speed higher than switching
speed (overspeed)
Speed below switching speed
Tab. 2:
LED activity indicator