Baumer Hübner
Electrical installation
|
6
V1, T1 | HMG10 & HMG10P DeviceNet
Operating Manual
29
1 2
3
4
5
6
7
8
9
Ill. 4:
Connecting the supply cable
1
Torx / slotted screw M4x32 mm
2
Washer A4 (DIN 137)
3
DeviceNet bus terminal box
4
D-SUB connector
5
D-SUB socket
6
Terminals
7
Cable shield
8
Cable gland M16x1.5 mm (for cable di-
ameter 5-9 mm)
9
Connection cables (cable diameter 5-9
mm)
Tool
n
20 mm
n
17 mm
Instruction:
a) Loosen the screws at the terminal box.
b) Remove the DeviceNet terminal box from the encoder.
c) Loosen the cable gland at the terminal box.
d) Insert the connection cables into the cable glands.
e) Assign the supply cables to the terminals.