MOUNTING / MOUNTING TO DRIVE SHAFT
MB252EN - 11173969, 16A1, Baumer_HMG10-DeviceNet_II_EN
10/33
4.3.3
Version with through hollow shaft
)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error, see
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder�
» Lubricate drive shaft!
)
Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
Loosen the screw
Tighten the screw
Mt = 2-3 Nm
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
TX 10
1�6x8 mm
10 mm