MB126 - 11055737
Baumer_GT7_II_DE-EN (14A1)
22
10
Type
Open-
circuit
voltage
(DC)
Minimum load required
depending on speed range
[rpm]
Maximum
operating
speed
Armature
resistance
Armature
inductance
0 - 3000:
0 - 6000:
0 - n
max
:
U
0
[mV/rpm]
R
L
[kΩ]
R
L
[kΩ]
R
L
[kΩ]
n
max
[rpm]
R
A
(20°C)
[Ω]
L
A
[mH]
GT7.08L/4
10
10
≥5
≥12
≥27
9000
60
20
GT7.08L/4
20
20
≥20
≥48
≥108
9000
230
80
GT7.08L/4
30
30
≥45
≥108
≥243
9000
550
180
GT7.16L/4
40
40
≥40
≥96
≥216
9000
410
160
GT7.16L/4
60
60
≥90
≥215
≥223
6100
760
360
Superimposed ripple (for
τRC = 0.3 ms):
≤0.6% peak-peak
≤0.25% rms
10.3
Type data
R
A
L
A
U
0
(n)
U(n)
R
L
2A1
R
2A2
Tachogenerator
C
U(n) = U
0
(n)
R
L
≈ U
0
(n)
R
A
+ R
L
τ
RC
≈ R
. C
τ
A
≈
L
A
R
L
for R > R
L
>> R
A
-n
U(n)
-U(n)
n
U
0
(n) ≈ U(n)
Polarity for positive direction of rotation (see section 5):
2A1:
+
2A2:
-
(VDE)
10.4