2  Safety and operating instructions 

Intended use 

  The encoder is a precision measuring device that is used to record positions and speeds. It provides 

measuring values as electronic output signals for the subsequently connected device. It must not be used 
for any other purpose. Unless this product is specially labeled, it may not be used for operation in 
potentially explosive environments. 

  Make sure by appropriate safety measures, that in case of error or failure of the encoder, no danger to 

persons or damage to the system or operating facilities occurs. 
 

Personnel qualification 

  Installation and assembly of this product may be performed only by a person qualified in electronics and 

precision mechanics. 
 

Maintenance 

  The encoder is maintenance-free and must not be opened up nor mechanically or electronically modified. 

Opening up the encoder can lead to injury. 

 

Disposal 

  The encoder contains electronic components. At its disposal, local environmental guidelines must be 

followed. 

 

Mounting 

  Solid shaft: Do not connect encoder shaft and drive shaft rigidly. Connect drive and encoder shaft with a 

suitable coupling.  

  Hollow shaft: Open clamping ring completely before mounting the encoder. Foreign objects must be kept 

at a sufficient distance from the stator coupling. The stator coupling is not allowed to have any contact to 
the encoder or the machine except at the mounting points. 

 

Electrical commissioning 

  Do not proceed any electrical modifications at the encoder. 

  Do not proceed any wiring work while encoder is live. 

  Do not remove or plug on connector whilst under power supply. 

  Ensure that the entire system is installed in line with EMC/EMI requirements. Operating environment and 

wiring have an impact on the electromagnetic compatibility of the encoder. Install encoder and supply 
cables separately or far away from sources with high emitted interference (frequency converters, 
contactors, etc.).  

  When working with consumers with high emitted interference provide separate encoder supply voltage. 

  Completely shield encoder housing and connecting cables. 

  Connect encoder to protective earth (PE) using shielded cables. The braided shield must be connected to 

the cable gland or connector. Ideally, aim at dual connection to protective earth (PE), i.e. housing by 
mechanical assembly and cable shield by the downstream devices. 
 

Supplementary information 

 

The present manual is intended as a supplement to already existing documentation (e.g. catalogues, data 
sheets or mounting instructions

)

Содержание EFL580

Страница 1: ...08 16 174 02 066 1 Subject to modification in technic and design www baumer com Errors and omissions excepted Manual Absolute encoders with BiSS C interface...

Страница 2: ...1 Introduction 4 1 1 Product assignment 4 2 Safety and operating instructions 5 3 Introduction 6 4 Functional description 7 4 1 The BiSS Frame 7 4 2 Processing time per request 7 4 3 Bus reset 7 5 Sen...

Страница 3: ...tion compiled in the present manual Baumer nor the author will accept any liability for direct or indirect damages resulting from the use of the present information At any time we should be pleased re...

Страница 4: ...1 1 Product assignment Product Description GBPAH Multiturn through hollow shaft GBPAS Multiturn blind hollow shaft GBUAH Singleturn through hollow shaft GBUAS Singleturn blind hollow shaft GBPAW Mult...

Страница 5: ...upling Hollow shaft Open clamping ring completely before mounting the encoder Foreign objects must be kept at a sufficient distance from the stator coupling The stator coupling is not allowed to have...

Страница 6: ...ast and safe exporting of sensor data and simultaneous accessing of the slave registers In the point to point configuration only one device with one slave sensor is operated on the master The BiSS int...

Страница 7: ...Master is sent to all slaves via the line MA as an inverse signal level of the BiSS timeout The addressed slave responds with the CDS Control Data Slave bit which is always transmitted in the first b...

Страница 8: ...f all data channels The slaves can only correctly signal the BiSS timeout in the BiSS frame if all SLO lines have the signal level 0 at the start of the BiSS timeout The master sends a leading zero be...

Страница 9: ...ation of the BiSS timeout in the slave The control frame can be canceled at any time with the transmission of 14 0 bits The start bit of a control frame must be preceded by at least 14 cycles with CDM...

Страница 10: ...8 is reading the encoder error status 0x00 mains no error present Bit 0 is the only one to signal error ERR_L infrared LED current limit error in the BiSS C frame The warning bit is not used Transmiss...

Отзывы: