7
|
Functions
Baumer
36
Operating Manual
DAB10, DST53, DST76 | V3
7.3.3
Parameterization of the analog output (only for product variants xxI and xxU)
Analog output parameterization allows you the following settings:
n
Selecting the output signal (
Signal Selection
)
n
Analog output scaling
(Signal Adjustment
)
n
Parameterization of the signal range of the analog output (
Signal Limits
): 2-point adjustment
of process value and analog signal
n
Alarm signal parameterization (
Signal Alarm
)
7.3.3.1
Selection of the output signal (Signal Selection)
With the
Signal Selection
function you can define the signal that is presented at the analog out-
put. The following options are available:
n
Alarm signal
n
Input signal (unprocessed process value) with a sample rate of 8 kS/s
n
Additional functions with 2 kS/s:
▪ Process value (processed)
▪ Min. process value
▪ Max. process value
▪ Peak peak process value (delta between min. and max. process value)
▪ Sample & Hold
IO-Link Parameter: Analog output signal selection (Signal Selection)
Parameter denotation
Description
Analog Output.Source
Selecting the source of the process value that is dis-
played as an analog output signal:
n
0
: Disabled (Analog Output Alarm)
n
1
: Current Process Value (8 kS/s)
n
3
: Minimum Process Value (2 kS/s)
n
4
: Maximum Process Value (2 kS/s)
n
5
: Peak Peak Process Value (2 kS/s)
n
6
: Sample and Hold Process Value (2 kS/s)
n
7
: Sample and Hold Delta Process Value (2kS/s)