Functions
|
7
V3 | DAB10, DST53, DST76
Operating Manual
25
7.2
Observation
In the
Observation
register, next to the processed process value, peak values and sample and
hold process values are presented.
INFO
Resetting memory values and sample and hold
Memory values and sample and hold can each be reset via the cyclic data or via one of the two
I/O pins. The peak value is reset via the signal
Memory Reset
, while sample and hold is reset
via the signal
Sample and Hold Trigger
.
IO-Link parameter: Peak value storage and sample and hold (measured values)
Parameter designation
Description
Process Value.Processed
Presentation of the current process value (processed).
Process Value.Minimum
Presentation of the min. process value since the last
memory reset.
Process Value.Maximum
Presentation of the max. process value since the last
memory reset.
Process Value.Peak Peak
Presentation of the peak peak process value (delta be-
tween min. and max. process value) since the last mem-
ory reset.
Process Value.Sample and Hold
Presentation of the process value that was held during
the last S&H trigger.
Process Value.Sample and Hold
Delta
Presentation of the difference between the process
value held during the last S&H trigger and the current
process value.