29
Baumer_AMG81-T1_II_DE-EN (19A3)
MB050T1 - 11081758
9
Technical data
9
Technical data
9.1
Technical data - electrical ratings
•
Voltage supply:
9...30 VDC
•
Consumption w/o load:
≤100 mA (per interface SSI)
≤250 mA (per interface bus)
•
Initializing time:
≤200 ms after power on
•
Interfaces: SSI
Profibus-DP V0
CANopen®
•
Function: Multiturn
•
Transmission rate:
9.6...12000 kBaud (Profibus)
10...1000 kBaud (CANopen®)
•
Profile conformity:
Profibus-DP V0
CANopen® CiA DSP 406 V 3.0
•
Device adress:
Rotary switch in bus cover
•
Steps per turn:
8192 / 13 bit
•
Number of turns:
4096 / 12 bit
65536 / 16 bit
•
Additional output signals:
Square-wave TTL (RS422)
Square-wave HTL
•
Sensing method:
Optical
•
Code:
Gray (version SSI)
•
Code sequence:
CW default
•
Inputs:
SSI clock (version SSI)
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Programmable parameters: Depending on the selected absolute interface
•
Diagnostic function:
Position or parameter error
•
Status indicator:
DUO-LED integrated in bus cover
•
Approvals:
CE
UL approval / E256710