6
|
Electrical installation
Baumer
20
Operating Manual
OM20/ OM30 RS485 with Modbus RTU | V1
6
Electrical installation
6.1
Pin assignment
4
0 V
3
analog
2
1
+Vs
teach in
1
2
4
3
1
+Vs
2
Rx/Tx -
3
0 V
4
Rx/Tx +
6.2
Connection diagram
WH (2)
BK (4)
Rx/Tx -
Rx/Tx +
RS 485
0 V
BU (3)
BN (1)
+V
S
1
BN – Brown
2
WH – White
3
BU – Blue
4
BK – Black
6.3
Connecting the sensor to electricity
Instruction:
a) Ensure that the system is disconnected from power.
b) Connect the sensor according to the pin assignment.
Содержание 11233538