background image

12

13

BEFORE USING YOUR COOKER HOB

RECOMMENDED ENVIRONMENTAL SAFEGUARDS

Before you use this cooker hob we suggest that you read the
instructions carefully and keep them for future consultation.
• Keep packing material (plastic bags, styrofoam blocks, etc...) out of

the reach of children as they can be dangerous.

• Make sure the cooker hob is intact and has not undergone damage

during shipment.

• Make sure the installation and gas and/or electric connections are

made by a qualified expert according to the manufacturer’s
instructions and in compliance with the local regulations in effect.

• Any exhaust hoods installed over the cooker hob should be

positioned at the height indicated (pict. A).

Packing: the packing material can be recycled and is marked with the
recycle symbol. Pieces of styrofoam, if any, should not be disposed of
carelessly. Dispose of this waste material at local dumps.

Product: the cooker hob is made of materials suitable for recycling.
Dispose of it in respect of the local regulations for waste disposal, after
making sure it cannot cause any damage. We recommend cutting the
power cable.

FOR INSTALLERS

TECHNICAL INFORMATION

Installation of BUILT-IN UNIT

To install built-in cooker hobs make an opening in the top of the cabi-
net with measurements A-B (pict. 1) as indicated in mm. in the table
below:

For the flush-mount version of the hobs (model 7043, 7044, 7045)
please refer to the specific instructions inside the box.

Note: Before installing make sure the local gas distribution system (type
and pressure of the gas) and settings of the cooker hob are compatible
(see rating plate).

Before installing the unit, remove any protective film. 
Any laminate on the walls of the cabinet or adjacent appliances must
be heat resistant (heating protection "Y" according to standards EN
60335-2-6).

FASTENING OF UNIT 

Apply the sealing gasket along the edge of the opening taking care to
overlap the joints (fig. 2). Place the cooker hob in the opening on the
cabinet. With a tool, slide plate A and fasten it with screw B (fig. 3). To
install cooker hobs size 76x50, mod. SOFT 79x50 and mod. FILO TOP,
see the installation instructions shown in pict. 3/A.
Fit hook B in angle iron A welded on the unit (fig. 3/A) taking care to
block it in the holes provided, depending on the thickness of the TOP.
Turn tab C and position it under the TOP, then tighten screw D. Trim
the part of the gasket extending beyond the cooker hob. For models
with sliding fastening hooks, see the instructions in the package.
For models 7045, 7041, 7042, see pict. 3/B.

IMPORTANT!!!

The counter top under the hob must be at least 3 mm below the
bottom and should have an opening for passage of the gas pipe and
electric wires measuring at least 50x50 mm. The adjacent surfaces
(bottom and back) of any cabinets over the counter top must be at least
50 mm above it. In case of elements sold complete with cabinet, the
instructions for installation of the cooker hob are provided in the
manual for the cabinet.
Installation must be made by a kitchen installation expert.

CONNECTION TO GAS MAINS

Must comply with the local regulations in effect. Connection must be
made with flexible steel tubing against the wall or with a rigid copper or
steel pipe (pict. 4-5).

IMPORTANT!!!

If flexible stainless steel tubing is used, it must be installed in such a
way that it does not come into contact with any moving parts, but
should pass in a point free of encumbrances so that it can be inspec-
ted along its entire length. After connecting the unit to the gas mains
always check the seal of the connection using a solution of soapy water.
Never check the seal using a flame.
The gas connector is a 1/2” gas threading ISO R7 conical connector.
If the cooker hob is installed in a cabinet with doors, it is important for
the rear wall of the cabinet to provide good airing. In case of a column
unit, adjacent to the cooker hob, it should be at least 100 mm away
from the outer edge.
The gas supply system must comply with the local standards in effect (see
chapter “National Reference Standards”).

CONNECTION TO POWER MAINS

• Connection to the power mains must be made by a qualified person

according to the regulations in effect.

• The installer is responsible for proper connection complying with the-

safety regulations.

• The cable supplied with a unit (if supplied without the plug) should

be provided with a plug suitable for the load indicated on the rating
plate, which should be plugged into a suitable grounded outlet.

• Connection can be made directly to the mains after inserting an omni

polar circuit breaker with minimum opening of 3 mm between the
unit and the mains, suitable for the load and complying with the
regulations in effect.

• The ground cable must not be cut off by the switch.
• The power cable must not touch parts that exceed room temperature

(pict. A)

B

A

R

29x50 cooker hobs

480

270

59x50 cooker hobs

480

570

76x50 Mod. 7024V

480

740

86x50 cooker hobs

480

840

76x50 Mod. 7065V

480

570/740

79x50 cooker hobs

480

770

116x50 cooker hobs

480

1140

Rondò Ø 52 units

diam. 500

/

79x50 cooker hobs Soft

480

770

135

92x54 cooker hobs

520

900

Cooker hobs angolare

(fig. 1A)

Dimensions of burner 

unit and counter

(pict. 

3)

(pict. 3/b)

(pict. 3/a)

(pict. 4)

(pict. 5)

(fig. 1)

(fig. 2

)

480

33

0

8

1

0

480

330

810

610

6

1

0

20x45∞

200x

45∞

(fig. 1A)

B

A

R

Содержание BT18.5SS

Страница 1: ...11 FOR INSTALLERS PAG 12 FOR THE USER PAG 15 TYPES OF COOKER HOBS PAG 76 ENGLISH ...

Страница 2: ...PORTANT The counter top under the hob must be at least 3 mm below the bottom and should have an opening for passage of the gas pipe and electric wires measuring at least 50x50 mm The adjacent surfaces bottom and back of any cabinets over the counter top must be at least 50 mm above it In case of elements sold complete with cabinet the instructions for installation of the cooker hob are provided in...

Страница 3: ...ata table To access the nozzle simply remove the cap and flame breaker To change the nozzles use a no 7 socket wrench pict 7 IMPORTANT In case of appliances installed previously always disconnect the power before performing any operation pict 6 B pict 6 pict 6 C pict 6 A pict 7 Nozzle pict 8 pict 9 pict 9A GAS COOKER HOBS RECOMMENDATIONS FOR ENERGY SAVINGS Use of cooker hobs The cooker hob is comp...

Страница 4: ...s follows raise and remove the burner cap remove the burner from its housing by pulling it upward soak it in hot soapy water rinse and dry thoroughly make sure none of the openings in the flame breaker is clogged correctly reassemble the flame breaker and cap pict 10 Note do not use the electric lighter when the burners are not in place ELECTRIC BURNER UNITS HOW TO USE THE ELECTRIC HOT PLATES The ...

Страница 5: ...W 6 Botones de comando LEGENDA A Chapa N Ø 145 1000 W 230 V B Chapa R Ø 180 2000 W 230 V C Chapa R Ø 145 1500 W 230 V D Chapa N Ø 180 1500 W 230 V 1 Queimador auxiliar 1000 W 2 Queimador semi rápido 1750 W 3 Queimador rápido 2700 W 4 Queimador de coroa tripla 3500 W 5 Queimador oval 2900 W 6 Manípulos de controle LEGENDE A Platte N Ø 145 1000 W 230 V B Platte R Ø 180 2000 W 230 V C Platte R Ø 145 ...

Страница 6: ...2900 W 6 Botones de comando LEGENDA A Chapa N Ø 145 1000 W 230 V B Chapa R Ø 180 2000 W 230 V C Chapa R Ø 145 1500 W 230 V D Chapa N Ø 180 1500 W 230 V 1 Queimador auxiliar 1000 W 2 Queimador semi rápido 1750 W 3 Queimador rápido 2700 W 4 Queimador de coroa tripla 3500 W 5 Queimador oval 2900 W 6 Manípulos de controle LEGENDE A Platte N Ø 145 1000 W 230 V B Platte R Ø 180 2000 W 230 V C Platte R Ø...

Отзывы: