10) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in
question.
To
do
this,
first
remove
the
burner
tops
using
a
wrench
“B”.
Now
unscrew
injector
“A”
(see
fig.
13)
and
fit
a
injector
corresponding
to
the
utili
s
ed
type
of
gas
in
its
place.
It
is
advisable
to
strongly
tighten the injector in
place.
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 9. The technician must reset any
seals on the regulating or pre-regulating devices.
The envelope with the injectors and the labels can
be included in the kit, or at disposal to the
authorized Customer Service Centre.
For the sake of convenience, the nominal rate table
also lists the heat inputs of the burners, the
diameter of the injectors and the working pressures
of the various types of gas.
BURNER ARRANGEMENT ON THE HOT PLATE
CONVERSIONS
FIG. 13
10
BURNERS
GAS
NORMAL
PRESSURE
mbar
NORMAL
RATE
INJECTOR
DIAMETER
1/100 mm
NOMINAL HEAT
INPUT (W)
N°
DESCRIPTION
g/h l/h
Min. Max.
1
ULTRA RAPID
G30
-
BUTANE
G31 - PROPANE
G20 - NATURAL
28-30
37
20
225
221
295
90
90
121 Y
1800
1800
1800
3100
3100
3100
2
RAPID
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
28-30
37
20
204
200
267
83
83
117 S
800
800
800
2800
2800
2800
3
SEMIRAPID
G30 -
BUTANE
G31 - PROPANE
G20 - NATURAL
28-30
37
20
127
125
167
65
65
97 Z
550
550
550
1750
1750
1750
4
AUXILIARY
G30
-
BUTANE
G31 - PROPANE
G20 - NATURAL
28-30
37
20
73
71
95
50
50
72 X
450
450
450
1000
1000
1000
13
SEMIRAPID
REDUCED
G30 -
BUTANE
G31 - PROPANE
G20 - NATURAL
28-30
37
20
102
100
133
58
58
85 Y
550
550
550
1400
1400
1400
TABLE
Содержание BHG900.6SS
Страница 1: ...INSTRUCTION MANUAL ...
Страница 15: ...14 TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION ...
Страница 17: ...16 ...
Страница 18: ......