24
Gas adjustment (Conversion to LPG)
All work must be carried out by a GASSAFE registered
engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o
Remove the pan-stands, burners and
flame spreaders
(A)
.
o
Unscrew the injector
(B)
and replace it
with the stipulated injector for the new gas
supply (see table on next page).
GENERAL INJECTORS TABLE
Kind of gas
Nozzle
mm/100
Burners
Power (in watts)
Max.
Min.
Natural
95/55/95
129
97
76
Wok
Rapid
Semi-rapid
Auxiliary
3800
3000
1750
1000
1700
1500
900
500
L.P.G.
Butane
Propane
65/41/65
87
65
51
Wok
Rapid
Semi-rapid
Auxiliary
3800
3000
1750
1000
1300
700
400
350
o
Reassemble all the burners carefully; in particular you should make
sure that the flame spreader is correctly placed on the burner.
o
IMPORTANT:
The minimum flow adjustment process must be
completed before the appliance is next used.