29
o
Put the gas seal into the elbow.
o
Fully tighten the elbow and seal onto the gas rail.
o
The elbow MUST be pointing in a downwards direction.
o
Gas pressure may be checked on a semi-rapid hob burner.
Remove the appropriate injector and attach a test nipple. Light
the other burners and observe that the gas pressure complies
with the gas standards in force.
o
IMPORTANT: On completion carry out a gas soundness
test.
Gas adjustment (Conversion to LPG)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o
Remove the pan-stands, burners and
flame spreaders (A).