background image

20131030SC_HB-EN_CP-CAM-AHD-Steel.doc

1 / 1

s/15.05.2014

Baudisch.CP-CAM-AHD ECO / MAXI 

Manual

History:

Version

Date

Name

Modification

1.0

30.10.2013

M.Schmidt

First draft

1.1

19.11.2013

M.Schmidt

Modification of the factory default values

Released last version:

Date

Name

Unit

KZZ

Signature

geprüft

TT.MM.JJJJ

DEV

geprüft

PF

geprüft

VT

geprüft

Kunde

gesehen

FE

freigegeben

GL

Содержание CP-CAM-AHD ECO / MAX

Страница 1: ...anual History Version Date Name Modification 1 0 30 10 2013 M Schmidt First draft 1 1 19 11 2013 M Schmidt Modification of the factory default values Released last version Date Name Unit KZZ Signature...

Страница 2: ...t a SIP door module MAXI PLUS or TouchMe MAXI 10 4 2 2 Stand alone operation 10 5 Configuration 11 5 1 Log in to the Web Interface 11 5 1 1 IP Settings 12 5 1 2 Video Stream Settings 12 5 1 3 User Man...

Страница 3: ...l voltage This symbol indicates important instructions that you should follow in any case to avoid injury or damage to or malfunction of the product This symbol indicates helpful hints 2 2 Softwarehis...

Страница 4: ...at the AUX port of the Baudisch SIP door module MAXI PLUS or the Baudisch TouchMe MAXI For stand alone operation the Baudisch CP CAM Supply Interface is available Features image sensor Progressive sc...

Страница 5: ...Baudisch SIP DisplayModule Baudisch SIP KeypadModule 16B Baudisch Diode MatrixModule Baudisch Central call ButtonModule Baudisch ButtonModule Baudisch Emergency Module Baudisch CP CAM Baudisch ASB_8Ou...

Страница 6: ...CO MAXI Version 1 1 Stand 19 11 2013 3 4 Scope of delivery Article No Name Description Baudisch CP CAM AHD ECO Complete module with V4A front panel and IP camera 36 0243 Baudisch CP CAM AHD MAXI Compl...

Страница 7: ...d 4x2 On wall box 33 1454A 1 fold 1x1 33 1454B 2 fold 2x1 33 1454C 3 fold 3x1 33 1454D 4 fold 4x1 33 1454H 5 fold 5x1 33 1454E 4 fold 2x2 33 1454F 6 fold 3x2 33 1454G 8 fold 4x2 Module frame FB 27 028...

Страница 8: ...CP CAM AHD ECO MAXI Version 1 1 Stand 19 11 2013 Article No Name Description Baudisch SIP door module MAXI PLUS 33 1000 MAXI 33 1384 PLUS 33 1119 V4A front panel Baudisch TouchMe MAXI 33 1310 Baudisch...

Страница 9: ...ouchMe To establish a connection with the CP CAM it is necessary that the PC laptop use is temporarily set to an IP adresse in the range of the CP CAM On delivery the 192 168 1 xxx address range is de...

Страница 10: ...sch SIP door module MAXI PLUS or the Baudisch TouchMe MAXI Connect the SIP door module MAXI PLUS either with a PowerOverEthernet PoE switch or with a 24V DC power supply and a ethernet switch or conne...

Страница 11: ...standard web browser In order to login on an IP Camera for the first time with its default settings proceed as follows Make sure that the camera is connected to the network Make sure that the camera...

Страница 12: ...ream in the left browser menu o Image Appearance Resolution Setting of the camera resolution QVGA 320x240 pixel is recommended for an image transmission to IP telephone Compression Value of the Imagec...

Страница 13: ...user proceed as follows o Select the user you want to change in the User List o Click on Modify o Assign the new user password o Click on Change User Settings To delete a user proceed as follows o Se...

Страница 14: ...the date in the video image rotation 0 o 0 90 180 270 compression 0 o 0 100 Value of the image compression fps 0 o 0 unlimited framerate only at Motion JPEG To specify the parameters enter a after th...

Страница 15: ...e Etablish a FTP connection to the IP camera Use the same username and password as the login on the webinterface Navigate to the following folder mnt flash etc httpd html viewer Copy the snomaxis xml...

Страница 16: ...age transmission from the integrated IP Camera are made Click on Operation Directory to make the following settings o Number SIP ID of the VideoDoorStation e g 100 o Title free to choose e g IP VideoD...

Страница 17: ...estore the factory settings proceed as follows Disconnect the camera from the power supply and ethernet Remove the four screws securing the rear cover and remove it Keep the Control button pressed whi...

Страница 18: ...on software that was developed by the OpenSSL Project for use in the OpenSSL ToolKit www openssl org API s Open API for software integration ONVIF specification www onvif org VAPIX from AXIS Communica...

Страница 19: ...tion JPEG Resolutions 4 3 320x240 480x360 640x480 800x600 16 9 640x360 1280x720 16 10 640x400 1024x640 1280x800 Frame rate 30 fps with all resolutions in H 264 and Motion JPEG Image settings Compressi...

Страница 20: ...onments DIN EN 61000 6 3 2011 09 Generic standards Emission standard for residential commercial and light industrial environments Operating displays LED network green 100MBit Connection flashes at dat...

Страница 21: ...udisch TouchMe to supply voltages of 110 230V AC If this isn t complied with in the absence of grounding the module may be damaged so that power is applied to housing and loss of life Connection Pin N...

Страница 22: ...20131030SC_HB EN_CP CAM AHD Steel doc 22 22 s 15 05 2014 Baudisch CP CAM AHD ECO MAXI Version 1 1 Stand 19 11 2013 6 3 Technical drawings 6 3 1 Baudisch CP CAM AHD Steel ECO...

Страница 23: ...20131030SC_HB EN_CP CAM AHD Steel doc 23 23 s 15 05 2014 Baudisch CP CAM AHD ECO MAXI Version 1 1 Stand 19 11 2013 6 3 2 Baudisch CP CAM AHD Steel MAXI...

Страница 24: ...19 11 2013 6 4 Support For questions and problems during startup please contact our support department support stentofonbaudisch com Manufacturing Baudisch Electronic GmbH Im Gewerbegebiet 7 9 D 7311...

Отзывы: